Six Classrooms, One Question: Who Is Accountable for the Mould at Parry Sound High School?
Ask AuntieGen | October 12, 2026
In September 2026, reports of soft flooring led to the discovery of water damage and mould beneath six modular classrooms at Parry Sound High School in Ontario. Students and staff were relocated while remediation took place.
The discovery came against a troubling construction history at the newly opened school.
Construction Problems Before Opening
In November 2025, the Near North District School Board reported ongoing construction deficiencies identified by its prime consultant.
In January 2026, the board terminated its general contractor, Van Horne Construction, citing defective work, unresolved deficiencies, scheduling problems, and construction liens. The contractor disputed the termination and initiated legal proceedings.
The school’s secondary section opened in June 2026. No evidence has been established connecting the earlier deficiencies directly to the classroom mould.
What Made the Classrooms Different?
Of the seven hexagonal modular classrooms, six were affected. The seventh, constructed and installed on-site by the board’s current contractor, was unaffected.
EBS Global, a Barrie-based modular construction company, documented manufacturing four hexagonal classrooms for the project. Its published account describes sections fabricated off-site, transported by truck, and assembled at the school.
Photographs show components outdoors during the project, but do not establish damaging exposure to rain or other moisture. The manufacturing history of all six affected classrooms has not been publicly documented.
The difference between the affected and unaffected units makes their construction methods, materials, and installation records particularly relevant.
How Could Mould Develop Beneath New Flooring?
Water can enter floor assemblies through leaks, condensation, inadequate weatherproofing, or moisture exposure during construction.
When damp materials are enclosed beneath finished flooring, restricted drying can allow deterioration and fungal growth to develop out of sight.
The timing and source of the infiltration at Parry Sound have not been established publicly.
Were Proper Inspections Conducted?
Construction inspections should verify compliance with applicable specifications, including protection of moisture-sensitive materials and flooring installation requirements.
Moisture measurements can identify damp substrates before flooring is installed. Routine visual inspections may reveal warning signs such as staining, leaks, or deterioration.
Air sampling does not reliably establish whether concealed building materials are dry.
The publicly available information does not confirm what moisture inspections were conducted on the affected floor assemblies or whether identified deficiencies were corrected before occupancy.
What Did Remediation Accomplish?
The school board reported removing affected flooring, subfloor materials, vapour barriers, and insulation.
A third-party environmental consultant subsequently conducted air-quality testing, and the board reported environmental clearance.
Those results address airborne conditions at the time of testing. They do not independently establish that the underlying moisture problem was permanently corrected.
The consultant’s complete findings and clearance criteria have not been independently reviewed.
Who Pays for the Damage?
Responsibility depends on the cause of the failure and the contractual obligations of the manufacturers, designers, installers, contractors, and construction consultants involved.
The school board has not publicly established which party, if any, is liable for the damage.
Remediation, replacement materials, environmental testing, and classroom relocation all carry costs. Whether those expenses will be recovered through warranties, insurance, or contractual remedies remains unanswered.